MQTT Client SL Library Documentation

Company:

CODESYS

Title:

MQTT Client SL

Version:

1.13.0.0

Categories:

Application|Utils

Namespace:

MQTT

Author:

CODESYS Development GmbH

Placeholder:

MQTT_Client_SL

Description [1]

MQTT (Message Queuing Telemetry Transport) is an open-source IoT protocol that allows for the transmission of telemetry data as messages between devices. Device communication always takes place by means of an MQTT broker (e.g. Mosquitto https://mosquitto.org/). Messages are sent and subscribed to based on topics. A topic corresponds to a path (e.g. device1/temperature). Subscribing to messages is done by specifying a topic filter. Wildcards are also permitted (+ for one level and # for multiple levels). The message format is not fixed, which means that a JSON string or any data structure can be transmitted.

With the “MQTT Client SL” library, messages can be sent from a CODESYS controller to an MQTT broker, and messages can be subscribed to based on topics.

The “MQTT Client SL” package contains the following components:
  • MQTT Client SL library with the following function blocks:
    • MQTTClient FB for establishing an MQTT link

    • MQTTPublish FB for sending messages

    • MQTTSubscribe FB for subscribing to messages

  • Sample project “MQTT Client SL Example.project” with a visualization for sending and receiving messages

  • Description of the function blocks (CHM help file)

  • Data sheet (German/English)

Supported functions

  • Publishing and subscription of messages based on MQTT V3.1.1 and MQTT V5.0

  • TLS encryption

  • Client certificates (transfer of a certificate handle)

  • Quality of Service: 0, 1, and 2 (QoS0, QoS1, QoS2) for the last will, publisher, and subscriber

  • Data type “Topics”: WSTRING

  • Maximum size of a topic: 1024

  • The maximum package size and payload size can be configured by means of a parameter list.

  • Multitasking and multicore support (MQTTClient, MQTTPublish, and MQTTSubscribe can each be run on different tasks or CPU cores.)

  • Last will messages (QoS0, QoS1, QoS2)

  • Wildcards (# and +)

  • MQTT over WebSocket

Supported MQTT V5 functions

  • Session expiry: see MQTTConnectProperties.udiSessionExpiryInterval

  • Message expiry: see MQTTPublishProperties.udiMessageExpiryInterval and MQTTWillProperties.udiMessageExpiryInterval

  • Reason codes: The reason code of the last response is set to the output MQTTClient.eReaonCode

  • Reason strings: see MQTTConnackProperties.wsReasonString and

  • Server disconnect: The server can send a DISCONNECT packet to the client. The reason code will be set to MQTTClient.eReaonCode

  • Payload format and content type: see MQTTPublishProperties.bPayloadFormatIndicator, MQTTWillProperties.bPayloadFormatIndicator, MQTTPublishProperties.wsContentType and MQTTWillProperties.wsContentType

  • Request / Response: see MQTTPublishProperties.wsResponseTopic and MQTTWillProperties.wsResponseTopic

  • Shared Subscriptions: A Shared Subscription is identified using a special style of Topic Filter. The format of this filter is: $share/{ShareName}/{filter}

  • Subscription ID: see MQTTSubscribeProperties.udiSubscriptionIdentifier

  • Topic Alias: see MQTTPublishProperties.uiTopicAlias

  • Flow control: see MQTTConnackProperties.uiReceiveMaximum and MQTTConnectProperties.uiReceiveMaximum

  • User properties: see MQTTConnectProperties.userProperties, MQTTConnackProperties.userProperties, MQTTConnectProperties.userProperties, MQTTPublishProperties.userProperties, MQTTSubscribeProperties.userProperties and MQTTWillProperties.userProperties

  • Maximum Packet Size: see MQTTConnectProperties.udiMaximumPacketSize, MQTTConnackProperties.udiMaximumPacketSize

  • Optional Server feature availability: see MQTTConnackProperties.bMaximumQoS, MQTTConnackProperties.bRetainAvailable, MQTTConnackProperties.bWildcardSubscriptionAvailable, MQTTConnackProperties.bSubscriptionIdentifierAvailable, MQTTConnackProperties.bSharedSubscriptionAvailable

  • Enhanced authentication: see MQTTConnectProperties, MQTTConnackProperties and MQTTAuthProperties

  • Subscription options: see MQTTSubscribeProperties.xNoLocalOption, MQTTSubscribeProperties.xRetainAsPublished and MQTTSubscribeProperties.eRetainHandling,

  • Will delay: see MQTTWillProperties.udiWillDelayInterval

  • Server Keep Alive: see MQTTConnackProperties.uiServerKeepAlive

  • Assigned ClientID: see MQTTConnackProperties.wsAssignedClientIdentifier

  • Server reference: see MQTTConnackProperties.wsServerReference

Contents:

Indices and tables